Support for Ademco Alarm Systems

Code changing

Important: All code changing keypresses MUST be done quickly in succession with no pauses.
If it doesn’t work, you probably paused.

To add a user code, enter the 4-digit master code, followed by 8, then the 2 digit user number (between 02 and 06). Immediately followed by the new code you want to use. Be sure to keep track of which user number you assigned to a code, you’ll need that to delete a user code.

To delete a user code, enter the 4-digit master code, followed by 8, then the 2 digit user number (between 03 and 06), followed by the master code again.

Bypassing

To bypass a zone, simply press your 4 digit code, followed by [6], followed by the two-digit zone number (01-64). The system will flash the bypassed zone number(s). You may then arm the system the same way you normally do. Note: Bypassed zones will clear after a successful arm and disarm. They are only stored for one arming period, after which all zones return to non-bypassed.

Chime Mode

To turn on or off the keypad chime, press your four digit code, followed by the [9] button.

Please call us at 281.591.1944 if you need further assistance.